--- title: "CL Port Diagrams - Multi-Homed" slug: "cl-port-diagrams-multi-homed" description: "CL Port Diagrams - Multi-Homed" updated: 2026-10-26T23:15:21Z published: 2026-10-26T23:15:21Z canonical: "docs.vastdata.com/cl-port-diagrams-multi-homed" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.vastdata.com/llms.txt > Use this file to discover all available pages before exploring further. # CL Port Diagrams - Multi-Homed > [!NOTE] > ℹ️ Info > > The Green Port - the leftmost RJ45 on the Cascade Lake CNode (The Green Port) is “reserved” and is not used in a VAST Deployment. > [!WARNING] > ⚠️ Warning > > Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance. > [!NOTE] > ℹ️ Note > > Skip NIC cannot be used with multi-homed configurations. ## Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with IB+ETH Multi-homed ![Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with IB+ETH Multi-homed](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/75dd2c34-f72f-49de-b3ac-10ef2cc5bf40.png?sv=2026-02-06&spr=https&st=2026-11-08T10%3A14%3A39Z&se=2026-11-08T11%3A14%3A39Z&sr=c&sp=r&sig=%2FfjrSs6goa82b9UZBrUlxQ9nQDws9qJ8fnbV03TIDQA%3D) | **Cascade Lake CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | CNode 1 | | | | | 2 | CNode 2 | | | | | 3 | CNode 3 | | | | | 4 | CNode 4 | | | | | 5 | PSU 1 | | | | | 6 | PSU 2 | | | | | 7 | enp94s0f0 | Right Card – Left Port | Internal | 5e:00.0 | | 8 | enp94s0f1 | Right Card – Right Port | Internal | 5e:00.1 | | 9 | ib0 | Left NIC - Left Port | Northbound / Split | 3b:00.1 | | 10 | enp59s0f0 | Left NIC - Right Port | Northbound / Split | 3b:00.0 | | 11 | eno1 | 1 GbE Port 1 (Left) | MGMT/IPMI (*TECH) | | | 12 | eno2 | 1 GbE Port 2 (Right) | TECH (*MGMT) | | *in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1). --- ## Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with ETH+IB Multi-homed ![Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with ETH+IB Multi-homed](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/75dd2c34-f72f-49de-b3ac-10ef2cc5bf40.png?sv=2026-02-06&spr=https&st=2026-11-08T10%3A14%3A39Z&se=2026-11-08T11%3A14%3A39Z&sr=c&sp=r&sig=%2FfjrSs6goa82b9UZBrUlxQ9nQDws9qJ8fnbV03TIDQA%3D) | **Cascade Lake CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | CNode 1 | | | | | 2 | CNode 2 | | | | | 3 | CNode 3 | | | | | 4 | CNode 4 | | | | | 5 | PSU 1 | | | | | 6 | PSU 2 | | | | | 7 | enp94s0f0 | Right Card – Left Port | Internal | 5e:00.0 | | 8 | enp94s0f1 | Right Card – Right Port | Internal | 5e:00.1 | | 9 | enp59s0f1 | Left NIC - Left Port | Northbound / Split | 3b:00.1 | | 10 | ib0 | Left NIC - Right Port | Northbound / Split | 3b:00.0 | | 11 | eno1 | 1 GbE Port 1 (Left) | MGMT/IPMI (*TECH) | | | 12 | eno2 | 1 GbE Port 2 (Right) | TECH (*MGMT) | | *in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1). --- ## Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with IB + ETH Multi-homed ![Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with IB + ETH Multi-homed](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/75dd2c34-f72f-49de-b3ac-10ef2cc5bf40.png?sv=2026-02-06&spr=https&st=2026-11-08T10%3A14%3A39Z&se=2026-11-08T11%3A14%3A39Z&sr=c&sp=r&sig=%2FfjrSs6goa82b9UZBrUlxQ9nQDws9qJ8fnbV03TIDQA%3D) | **Cascade Lake CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | CNode 1 | | | | | 2 | CNode 2 | | | | | 3 | CNode 3 | | | | | 4 | CNode 4 | | | | | 5 | PSU 1 | | | | | 6 | PSU 2 | | | | | 7 | ib0 | Right Card – Left Port | Internal | 5e:00.0 | | 8 | ib1 | Right Card – Right Port | Internal | 5e:00.1 | | 9 | ib0 | Left NIC - Left Port | Northbound / Split | 3b:00.1 | | 10 | enp59s0f0 | Left NIC - Right Port | Northbound / Split | 3b:00.0 | | 11 | eno1 | 1 GbE Port 1 (Left) | MGMT/IPMI (*TECH) | | | 12 | eno2 | 1 GbE Port 2 (Right) | TECH (*MGMT) | | *in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1). --- ## Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with ETH + IB Multi-homed ![Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with ETH + IB Multi-homed](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/75dd2c34-f72f-49de-b3ac-10ef2cc5bf40.png?sv=2026-02-06&spr=https&st=2026-11-08T10%3A14%3A39Z&se=2026-11-08T11%3A14%3A39Z&sr=c&sp=r&sig=%2FfjrSs6goa82b9UZBrUlxQ9nQDws9qJ8fnbV03TIDQA%3D) | **Cascade Lake CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | CNode 1 | | | | | 2 | CNode 2 | | | | | 3 | CNode 3 | | | | | 4 | CNode 4 | | | | | 5 | PSU 1 | | | | | 6 | PSU 2 | | | | | 7 | ib0 | Right Card – Left Port | Internal | 5e:00.0 | | 8 | ib1 | Right Card – Right Port | Internal | 5e:00.1 | | 9 | enp59s0f1 | Left NIC - Left Port | Northbound / Split | 3b:00.1 | | 10 | ib0 | Left NIC - Right Port | Northbound / Split | 3b:00.0 | | 11 | eno1 | 1 GbE Port 1 (Left) | MGMT/IPMI (*TECH) | | | 12 | eno2 | 1 GbE Port 2 (Right) | TECH (*MGMT) | | *in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1). > [!NOTE] > ℹ️ Note > > Using the Reverse NIC functionality together with Multi-home is supported, but has extremely limited use cases. Thus it is not documented here.