--- title: "HPE Gen5 Genoa Port Diagrams - Multi-Homed" slug: "hpe-gen5-genoa-port-diagrams-multi-homed" description: "HPE Gen5 Genoa Port Diagrams - Multi-Homed" updated: 2026-10-26T23:15:21Z published: 2026-10-26T23:15:21Z canonical: "docs.vastdata.com/hpe-gen5-genoa-port-diagrams-multi-homed" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.vastdata.com/llms.txt > Use this file to discover all available pages before exploring further. # HPE Gen5 Genoa Port Diagrams - Multi-Homed > [!WARNING] > ⚠️ Warning > > Networking is configured on a per-CNode basis, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance. > [!NOTE] > ℹ️ Note > > Skip NIC cannot be used with multi-homed configurations. ## HPE Gen5 Genoa CBox with dual CX7 NIC in ETH mode, Multi-homed ETH + IB > [!WARNING] > ⚠️ Warning > > Since this is a per-CNode setting, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance. ![f6376026-ba99-4751-a88e-30a1063ab81d.png](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/f6376026-ba99-4751-a88e-30a1063ab81d.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A08%3A29Z&se=2026-11-08T10%3A08%3A29Z&sr=c&sp=r&sig=pzLfwns9ET2AEgsw%2BXCQCebsKM0YBgqNDAQ976%2BxnbU%3D) | **HPE Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | enp7s0f0 | Right Card – Left Port | Internal | 07:00.0 | | 4 | enp7s0f1 | Right Card – Right Port | Internal | 07:00.1 | | 5 | enp134s0f0 | Left Card – Left Port | Northbound/Split | 86:00.0 | | 6 | ib0 | Left Card – Right Port | Northbound/Split | 86:00.1 | | 7 | BMC | Dedicated BMC port | (*IPMI) | | | 8 | enp200s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | c8:00.0 | | 9 | enp200s0f1 | 1 GbE Port 2 | (*MGMT) | c8:00.1 | | 10 | enp200s0f3 | 1 GbE Port 4 (Right) | TECH | c8:00.3 | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp200s0f1), and port 1 (enp200s0f0) is connected to the Dedicated BMC Port of the Peer Node --- ## HPE Gen5 Genoa CBox with dual CX7 NIC in ETH mode, Multi-homed IB + ETH > [!WARNING] > ⚠️ Warning > > Since this is a per-CNode setting, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance. ![8cc5d500-84f6-4588-a106-df2984ab2a6e.png](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/8cc5d500-84f6-4588-a106-df2984ab2a6e.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A08%3A29Z&se=2026-11-08T10%3A08%3A29Z&sr=c&sp=r&sig=pzLfwns9ET2AEgsw%2BXCQCebsKM0YBgqNDAQ976%2BxnbU%3D) | **HPE Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | enp7s0f0 | Right Card – Left Port | Internal | 07:00.0 | | 4 | enp7s0f1 | Right Card – Right Port | Internal | 07:00.1 | | 5 | ib0 | Left Card – Left Port | Northbound/Split | 86:00.0 | | 6 | enp134s0f1 | Left Card – Right Port | Northbound/Split | 86:00.1 | | 7 | BMC | Dedicated BMC port | (*IPMI) | | | 8 | enp200s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | c8:00.0 | | 9 | enp200s0f1 | 1 GbE Port 2 | (*MGMT) | c8:00.1 | | 10 | enp200s0f3 | 1 GbE Port 4 (Right) | TECH | c8:00.3 | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp200s0f1), and port 1 (enp200s0f0) is connected to the Dedicated BMC Port of the Peer Node --- ## HPE Gen5 Genoa CBox with dual CX7 NIC in IB mode, Multi-homed IB + ETH > [!WARNING] > ⚠️ Warning > > Since this is a per-CNode setting, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance. ![3bc4a2e4-dafe-4b8e-a0c4-0fefa625001c.png](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/3bc4a2e4-dafe-4b8e-a0c4-0fefa625001c.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A08%3A29Z&se=2026-11-08T10%3A08%3A29Z&sr=c&sp=r&sig=pzLfwns9ET2AEgsw%2BXCQCebsKM0YBgqNDAQ976%2BxnbU%3D) | **HPE Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | ib1 | Right Card – Left Port | Internal | 07:00.0 | | 4 | ib2 | Right Card – Right Port | Internal | 07:00.1 | | 5 | ib0 | Left Card – Left Port | Northbound/Split | 86:00.0 | | 6 | enp134s0f1 | Left Card – Right Port | Northbound/Split | 86:00.1 | | 7 | BMC | Dedicated BMC port | (*IPMI) | | | 8 | enp200s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | c8:00.0 | | 9 | enp200s0f1 | 1 GbE Port 2 | (*MGMT) | c8:00.1 | | 10 | enp200s0f3 | 1 GbE Port 4 (Right) | TECH | c8:00.3 | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp200s0f1), and port 1 (enp200s0f0) is connected to the Dedicated BMC Port of the Peer Node --- ## HPE Gen5 Genoa CBox with dual CX7 NIC in IB mode, Multi-homed ETH + IB > [!WARNING] > ⚠️ Warning > > Since this is a per-CNode setting, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance. ![cf64f0a9-5d59-48b4-bfe6-f4198cfdee80.png](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/cf64f0a9-5d59-48b4-bfe6-f4198cfdee80.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A08%3A29Z&se=2026-11-08T10%3A08%3A29Z&sr=c&sp=r&sig=pzLfwns9ET2AEgsw%2BXCQCebsKM0YBgqNDAQ976%2BxnbU%3D) | **HPE Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | ib1 | Right Card – Left Port | Internal | 07:00.0 | | 4 | ib2 | Right Card – Right Port | Internal | 07:00.1 | | 5 | enp134s0f0 | Left Card – Left Port | Northbound/Split | 86:00.0 | | 6 | ib0 | Left Card – Right Port | Northbound/Split | 86:00.1 | | 7 | BMC | Dedicated BMC port | (*IPMI) | | | 8 | enp200s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | c8:00.0 | | 9 | enp200s0f1 | 1 GbE Port 2 | (*MGMT) | c8:00.1 | | 10 | enp200s0f3 | 1 GbE Port 4 (Right) | TECH | c8:00.3 | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp200s0f1), and port 1 (enp200s0f0) is connected to the Dedicated BMC Port of the Peer Node --- > [!NOTE] > ℹ️ Note > > Using the Reverse NIC functionality together with Multi-home is supported, but has extremely limited use cases. Thus it is not documented here.