--- title: "SMC Gen5 Genoa Port Diagrams - Ethernet" slug: "smc-gen5-genoa-port-diagrams-ethernet" description: "SMC Gen5 Genoa Port Diagrams - Ethernet" updated: 2026-10-26T23:15:21Z published: 2026-10-26T23:15:21Z canonical: "docs.vastdata.com/smc-gen5-genoa-port-diagrams-ethernet" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.vastdata.com/llms.txt > Use this file to discover all available pages before exploring further. # SMC Gen5 Genoa Port Diagrams - Ethernet > [!WARNING] > ⚠️ Warning > > Networking is configured on a per-CNode basis, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance. ## SMC Gen5 Genoa CBox with single CX7 NIC in ETH Mode ![SMC Gen5 Genoa CBox with single CX7 NIC in ETH Mode](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/7f63436d-480c-4253-9c81-566247fd0c19.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A07%3A28Z&se=2026-11-08T10%3A07%3A28Z&sr=c&sp=r&sig=L0ga8xwgUYEBGYP4QRkRXB74T0I7stoJKmnX2Tu%2FOkg%3D) | **SMC Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | enp129s0f1 | Right Card – Left Port | Unified | 81:00.1 | | 4 | enp129s0f0 | Right Card – Right Port | Unified | 81:00.0 | | 5 | enp65s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | | | 6 | enp65s0f1 | 1 GbE Port 2 | (*MGMT) | | | 7 | enp65s0f3 | 1 GbE Port 4 (Right) | TECH | | | 8 | BMC | Dedicated BMC port | (*IPMI) | | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp65s0f1) and Port 1 (enp65s0f0) connected to the Dedicated BMC Port of the Peer Node --- ## SMC Gen5 Genoa CBox with Dual CX7 NIC in ETH + ETH mode ![SMC Gen5 Genoa CBox with Dual CX7 NIC in ETH + ETH mode](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/812ce1d1-8b3f-4559-84df-c1ef6f14522e.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A07%3A28Z&se=2026-11-08T10%3A07%3A28Z&sr=c&sp=r&sig=L0ga8xwgUYEBGYP4QRkRXB74T0I7stoJKmnX2Tu%2FOkg%3D) | **SMC Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | enp129s0f1 | Right Card – Left Port | Internal | 81:00.1 | | 4 | enp129s0f0 | Right Card – Right Port | Internal | 81:00.0 | | 5 | enp1s0f1 | Left Card – Left Port | Northbound/Split | | | 6 | enp1s0f0 | Left Card – Right Port | Northbound/Split | | | 7 | BMC | Dedicated BMC port | (*IPMI) | | | 8 | enp65s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | | | 9 | enp65s0f1 | 1 GbE Port 2 | (*MGMT) | | | 10 | enp65s0f3 | 1 GbE Port 4 (Right) | TECH | | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp65s0f1) and Port 1 (enp65s0f0) connected to the Dedicated BMC Port of the Peer Node --- ## SMC Gen5 Genoa CBox with dual CX7 NIC in ETH Mode with “Skip NIC - External” enabled > [!WARNING] > ⚠️ Warning > > Since this is a per-CNode setting, it is possible for a cluster to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance. When this flag is used, VAST instructs the auto-ports feature to disable the NIC that is typically designated for **northbound** traffic. This means that if you use this flag on a node with two NICs, the NIC designated for **internal** traffic will handle **both internal and external** (aka Unified) network traffic. This means the network interfaces that would typically be solely used for **northbound** connections are effectively disabled. This flag is not valid on a single NIC CNode. ![SMC Gen5 Genoa CBox with dual CX7 NIC in ETH Mode](https://cdn.us.document360.io/89b91113-5dc6-49db-86ec-57b16dc8ce56/Images/Documentation/a2e1ebd7-ffa9-4033-bc2c-80cb4a8052b5.png?sv=2026-02-06&spr=https&st=2026-11-08T09%3A07%3A28Z&se=2026-11-08T10%3A07%3A28Z&sr=c&sp=r&sig=L0ga8xwgUYEBGYP4QRkRXB74T0I7stoJKmnX2Tu%2FOkg%3D) | **SMC Gen5 Genoa CBox** | | --- | | Number | Name | Port Location | Function | PCIe B:D.F | | 1 | PSU 1 | | | | | 2 | PSU 2 | | | | | 3 | enp129s0f1 | Right Card – Left Port | Unified | 81:00.1 | | 4 | enp129s0f0 | Right Card – Right Port | Unified | 81:00.0 | | 5 | enp1s0f1 | Left Card – Left Port | Disabled | 01:00.1 | | 6 | enp1s0f0 | Left Card – Right Port | Disabled | 01:00.0 | | 7 | BMC | Dedicated BMC port | (*IPMI) | | | 8 | enp65s0f0 | 1 GbE Port 1 (Left) | MGMT/IPMI | | | 9 | enp65s0f1 | 1 GbE Port 2 | (*MGMT) | | | 10 | enp65s0f3 | 1 GbE Port 4 (Right) | TECH | | *In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp65s0f1) and Port 1 (enp65s0f0) connected to the Dedicated BMC Port of the Peer Node --- > [!NOTE] > ℹ️ Note > > The SMC Gen5 Genoa Platform does not support the Reverse NICs option.