Welcome to the new DOCS.vastdata.com. We've added new menus and a version selector, plus new persona and resource pages to help customers get started. Looking for a previous article? Use the docs search.

Collect VAST DataEngine Resource Values

Prev Next

ℹ️ Info

Outcome: A completed worksheet of names, network values, credentials, and generated keys used throughout the lab.

Before you begin: Obtain the DataEngine Site Survey details from your VAST Sales Engineer.

Next: Set Up VAST Tenants and VIP Pools

ℹ️ Info

If you are a VAST customer or partner, please contact your Sales Engineer for assistance filling out a DataEngine Site Survey document which will gather all of the below information as well as other critical environmental details.

Initial Configuration Values

Before starting the Initial VAST configuration, you will need to fill in several values throughout the process. Decide most of these values in advance to ensure consistent naming and speed up the process.

Input name

Example

Your value

VAST Identity provider name

de-lab-provider

AD/LDAP Identity Provider name

DataEngine tenant name

de-lab-tenant

DataEngine VIP pool name

de-lab-vippool

DataEngine VIP pool Gateway Address

DataEngine VIP pool start IP

172.200.205.13

DataEngine VIP pool end IP

172.200.205.18

DataEngine VIP pool subnet CIDR

16

DataEngine VIP pool VLAN Tag

DataEngine pool DNS name

de-lab-vippool

DataEngine S3 view policy name

de-lab-s3-policy

DataEngine NFS view policy name

de-lab-csi-policy

Docker repository view path

/de-lab-docker/images

DataEngine local/ldap/ad group name

de-lab-group

DataEngine local group GID

854321

DataEngine local/ldap/ad username

de-lab-user

DataEngine local user temporary password

<choose-a-strong-password>

Data Engine user S3 access key (generated)

(generated in a later step)

Data Engine user S3 secret key (generated)

(generated in a later step)

CSI Configuration Values

Values used only by the VAST CSI driver: its tenant, VIP pool, view policy, roles, and manager accounts. Skip this table if you are not installing the CSI driver.

Input name

Example

Your value

Trash folder GID

0

CSI tenant name

de-lab-csi-tenant

CSI VIP pool name

de-lab-csi-vippool

CSI VIP pool Gateway Address

CSI VIP pool start IP

172.200.205.19

CSI VIP pool end IP

172.200.205.24

CSI VIP pool subnet CIDR

16

CSI VIP pool VLAN Tag

CSI VIP pool DNS name

de-lab-csi-vippool

CSI view policy name

de-lab-csi-policy

CSI tenant-admin role name

de-lab-csi-tenant-admin

CSI service-account role name

de-lab-csi-service-account

CSI tenant-admin manager username

de-lab-csi-admin

CSI tenant-admin manager password

<choose-a-strong-password>

CSI driver manager username

de-lab-csi-driver

CSI driver manager password

<choose-a-strong-password>

DataEngine to Kubernetes and registry

Unique values for connecting VAST DataEngine to a Kubernetes cluster and registry. You may reuse DataEngine tenant, S3 view policy, bucket owner user, and DataEngine VIP pool from the table above. Certificates come from ~/.kubeconfig/rke2.yaml (certificate-authority-data, client-certificate-data, client-key-data).

Input name

Example

Your value

Kafka broker view path

/de-lab-broker

Kafka broker S3 bucket name

de-lab-broker

Kafka VIP pool name

de-lab-broker-vippool

Kafka VIP pool Gateway Address

Kafka VIP pool start IP

172.200.205.19

Kafka VIP pool end IP

172.200.205.24

Kafka VIP pool subnet CIDR

16

Kafka VIP pool VLAN Tag

Kafka VIP pool DNS name

de-lab-csi-vippool

Default topic name

de-default-topic

Topic partitions

1

Deadletter topic name

de-deadletter-topic

Topic partitions

1

Kubernetes cluster name

de-lab-rke2

Kubernetes API server URL

https://10.144.19.2:6443

Kubeconfig CA certificate (certificate-authority-data)

Kubeconfig client certificate (client-certificate-data)

Kubeconfig private key (client-key-data)

DataEngine namespace

vast-pipelines

Container registry name

de-lab-registry

Container registry base URL

http://10.144.19.8

Container registry authentication method

None

Worksheet completion check

Before continuing, fill in every value required by your chosen path. Leave generated access keys blank until the procedure creates them, then store them in an approved secret manager.