Summary
There are instances when access to an Intel 2U Quad Chassis dual-NIC CNode (without a VGA port for console) is unavailable via the standard Ethernet port. Here are a couple of reasons why this would be the case:
A usable tech port has not been defined with a valid configuration.
The CNode won’t boot, and you need a console to troubleshoot.
You need a console to re-image the CNode.
You can ping the tech port, but you cannot SSH in to fix a potential sshd problem.
Port Location
Location in chassis
Cascade Lake CNode (BMC port in red circle)

Location on the motherboard
Letter A represents the “dedicated management” port

Schematic
The Red line shows the path in the schematic for the “dedicated management” port

How to access the BMC port
Set your laptop's wired Ethernet port to 192.168.20.2/255.255.255.252
Ping the IP address 192.168.20.1
If successful, go to step 3
If unsuccessful, contact support
Point your web browser to 192.168.20.1
Authenticate: (it’s possible that other username/password combos are configured)
(Login to see passwords)
admin/123456
admin/admin
sysadmin/superuser
Once logged in, choose the Remote control tab and the iKVM over HTML5 option


You will now have a “serial” console to the CNode to do things like upgrade VastOS.